Power over USB
The Universal Serial Bus (USB) is designed to provide power as well as data communications. It can support 127 devices and has developed over the years from 1.5 Mb/s to 480 Mb/s. Currently (2014) a normal USB 2.0 has a low current limit of 100 mA and a high current limit of 500 mA at 5 V although a Thunderbolt connector is able to deliver 2 A at 5 V. Several years ago USB 3.0 was introduced which increased the theoretical bit rate by 10x’s to 5 Gb/s and raised the low current limit to 150 mA and the high current limit to 900 mA. More recently the USB 3.0 Promoter Group has announced a new specification which will allow USB 3.0 compatible sockets and cables to deliver up to 100 W by changing the voltage from 5 V to 20 V and increasing the current to 5 A.
USB also has limitations on the maximum cable length and in most cases this is restricted to 3m. With special cables this can be increased to over 6 m and with a USB bridge this can be extended to over 30 m. With such a large increase in power a single USB 3 SuperSpeed hub could be charging a laptop, powering an external hard drive as well as a second monitor. In future, TV manufacturers could include high-powered USB hubs to power nearby AV and communication equipment thereby reducing the need for multiple wall outlets.
Both USB and PoE (power over ethernet) bring power and communication functions together by using the data exchange capabilities to negotiate power need with the device in a number of incremental stages. This level of power control allows a common supply to deliver a range of different power profiles best suited to whichever device is connected to that particular port. For example, in the future a USB 3 might provide 60 W (20 V at 3 A) for a laptop or 5 to 10 W (5 V at 1 or 2 A) for an average smart phone.
The benefit of both of these systems is that they are well developed solutions that are supported by appropriate standards, research and testing. Components are readily available and system design expertise is relatively common.
In terms of network distribution efficiency both PoE and USB are still subject to conversion and distribution losses as any other network. Whilst a modern PoE injector may have a very efficient power supply, power is still converted from 230 V AC to approximately 50 V DC, distributed to the point-of-load and then converted again to what’s required by the end device. In the case of PoE the voltage is higher than USB potentially reducing its distribution losses although conductor sizes are relatively small.
In the domestic environment USB ports are much more common and could in the future be used not just for connecting between devices, for example a laptop and a peripheral, but also as an additional low voltage power outlet complimenting the existing 230 V wall outlet. This may reduce the need for individual power adapters and bulky 230 V plugs and sockets although where this is the case, USB sockets are still likely to be associated with a central device such as a TV or computer.
This article was created by --BRE. It was taken from The future of electricity in domestic buildings, a review, by Andrew Williams, published in November 2014.
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
BSRIA Briefing 2024: Sustainable Futures speakers
Redefining Retrofit for Net Zero Living 22 Nov.
Wall of support for post-Grenfell regulation of electricians
Call for a shake-up of the construction industry highlighted on radio.
Digital sustainability through future AEC tools
Bringing together industry and academia to meet challenges.
Skills gap for net zero highlighted to Minister for Industry
ECA convenes roundtable discussion at Portcullis House.
Evidencing Net Zero with the new UK buildings standard
Pilot version with detailed excel proforma out now!
Scottish Building Safety Levy, in consultation
From direct remediation and the RPDT, to the costs and alternatives.
Waves of warmer homes grants for the rental sector
Boosting energy efficiency standards for all rented homes.
A refocus of the National Planning Policy Framework
Key terms described in brief, as the consultation closes the evening of the 24th.
Fortified farmhouses of the unruly 16th-and 17th-century borders.
ECA shares advice for those who may be exposed to risks.
How to revolutionise UK housing with MMC
CIC and Supply Chain Sustainability School unveil a plan.
From the UKs largest manufacturer and supplier of lime.
From mud bricks to smart concrete
A brief history from 7000BC to a future on the moon.
Regulator of Social Housing publishes latest fire safety report
Covering remediation of 11 metre plus social housing sector buildings.
Apartment and Duplex Defects Remediation Bill 2024
Approved for priority drafting by Government of Ireland.
The long list with in the frame of key historical events.
Competence frameworks for sustainability in the built environment
Code of practice, core criteria consultation draft for comment.
New Floods Resilience Taskforce
With a wet met office autumn prediction.